12. SPECIFICATIONS
These are approximate measurements. They do not include data for any lamps or fixtures attached
to the ceiling fan.
Problem
Fan will not start.
Fan sounds noisy.
Fan wobble.
Solution
1. Check circuit fuses or breakers
2. Check all electrical connections to insure proper contact. CAUTION: Make
sure the main power is OFF when checking any electrical connection.
1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade brackets to the motor are tight.
3. Make sure wire nut connections are not rubbing against each other or the
interior wall of the switch housing.
CAUTION: Make sure main power is off.
4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan
disappear during this time.
5. If using an optional light kit, make sure the screws securing the glassware are
tight. Check that the light bulb is also secure.
6. Some fan motors are sensitive to signals from solid-state variable speed
controls. If you have installed this type of control, choose and install another type
of control.
7. Make sure the upper canopy is a short distance from the ceiling. It should not
touch the ceiling.
1. Check that all blade and blade arm screws are secure.
2. Most fan wobbling problems are caused when blade levels are unequal. Check
this level by selecting a point on the ceiling above the tip of one of the blades.
Measure this distance. Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. The distance deviation should be equal
within 1/8".
3. Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable.
4. If the blade wobble is still noticeable, interchanging two adjacent (side by side)
blades can redistribute the weight and possibly result in smoother operation.
WARNING: TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND
THE BLADE ARM WHILE INSTALLING, BALANCING THE BLADES, OR
CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN
ROTATING FAN BLADES.
11. TROUBLESHOOTING
Sterling Manor Patio
TM
1.43'
8.31
kgs
9.16
kgs
0.41
0.32
0.18
52
34
14
165
130
75
4121.22
3259.09
1514.43
79.25
95.86
108.17
RPM
CFM CFM/W
N.W. G.W. C.F.
120
120
120
Fan Size
52"
Speed Volts
Amps
Watts
High
Medium
Low